Sand Rammer
Model 42100
Model 42104
The Electronic Universal Sand Strength Machine determines the strength properties of clay and/or chemically bonded foundry sand specimens. This strength machine applies pressure on a sand specimen until failure to calculate the maximum force needed to break the specimen and then digitally displays the test results. Additional Information
Model 42104F
This accessory to the Electronic Universal Sand Strength Machine is used to measure the hot tensile strength of shell sands. Additional Information
Model 42106
Used to determine the fineness of foundry sands. Additional Information
Model 42108
Used to determine the amount of live bentonite clay present in a sand sample. Additional Information
Model 42109
Used to make standard tensile, transverse (except cold box) and hot distortion test pieces. Additional Information
Model 42109A
Connects to the Test Piece Blower or the Modified Test Piece Blower in order to control the gassing and purging sequence of the test specimen via the included electronic cables and supply lines. Additional Information
Model 42110
Used to prepare mixtures of clay bonded foundry sands and other chemical processing applications that require the high intensity mulling action of the wheels. Additional Information
Model 42111
Designed to mix liquid binders with sand that is common to all chemically bonded sand mixtures. Additional Information
Model 42114
Measures the expansion and high temperature plastic performance of chemically bonded sands when suddenly heated by liquid metal. Additional Information
Model 42115
Used to determine hot properties of molded sand with any type of binder (kaolinites, bentonites and chemical binders). Additional Information
Model 42116
Used to make standard clay bonded sand specimens for the High Temperature Compression Tester. Additional Information
Model 42119
Used to prepare a sand sample for the AFS Clay Tester. Additional Information
Model 42131
Stirs a water and sand mixture into suspension and drains the overlaying liquid after a preset settling time. Additional Information
Model 42136
Measures the amount of basic material present in the sand that is soluble in a dilute acid solution. Additional Information
Model 42141
Used to determine the friability (surface integrity) of a clay bonded foundry molding sand by measuring the ability of compacted molding sand to resist abrasion or scuffing within the first few millimeters at the surface of a prepared mold. Additional Information
Model 42142
Portable, lightweight and easy to operate. It incorporates an LCD display that clearly indicates the hardness number and completely eliminates any operator error associated with reading a mechanical scale. The instrument automatically records the maximum penetration value. Additional Information
Model 42142ADV
Portable, lightweight and easy to operate. It incorporates an LCD display that clearly indicates the hardness number and completely eliminates any operator error associated with reading a mechanical scale. The instrument automatically records the maximum penetration value. Additional Information
Model 42143
Portable, lightweight and easy to operate. It incorporates an LCD display that clearly indicates the hardness number and completely eliminates any operator error associated with reading a mechanical scale. The instrument automatically records the maximum penetration value. Additional Information
Model 42143ADV
Portable, lightweight and easy to operate. It incorporates an LCD display that clearly indicates the hardness number and completely eliminates any operator error associated with reading a mechanical scale. The instrument automatically records the maximum penetration value. Additional Information
Model 42145
Model 42152
The test apparatus consists of a heated bar in which a temperature gradient is established so that the left end of the bar is cooler than the right. Additional Information
Model 42159
This tester is designed to measure resistance to degeneration and plasticity of clay bonded sand upon impacting a target at a fixed velocity. Additional Information
Model PAB-P
Automatically ejects the specimen softly, ensuring high repeatability. Since the human “factor” can be eliminated, the test sample can be ejected without any further compaction. Additional Information
Model PEP
For the determination of the degree of curing in the lower zones and determination of curing time, especially the strip time. Additional Information
Model PFG
For the determination of the compressive, splitting, transverse, tensile, and twin transverse strength tests. Additional Information
Model PFG-MA
Electric motor instead of hand drive optional. Auxiliary instruments for determination of: Transverse-, shear-, splitting and increased strengths. Additional Information
Model PFP
Ensures a practically movement-free force measurement by means of an oscillating crystal-controlled sensor. Additional Information
Model PGD-E
Accurately measures the gas pressure from foundry sands. Additional Information
Model PKH
Used for determining core hardness and includes a calibration fixture, software package, and infrared receiver to download data to a PC. Additional Information
Model PLS
For the determination of the transverse strength of core sand, a standard sample specimen of reproducible quality must be made. Additional Information
Model 223100 / 42136-IS & PMK / PRK
For fast and complete removal of the clay coating and other material from the sand surface. Additional Information
Model PVF-C
A multi-purpose instrument used to determine strength properties of clay and/or chemically bonded foundry sand specimens. Additional Information